Condensation and corrosion
Moisture settles on glass, cold walls and ceilings, then attacks finishes, metalwork and electrical equipment.
INDOOR POOLS · HEAT-PIPE HEAT RECOVERY · CUSTOM-ENGINEERED
Humid pool-hall air is dried by a heat-pipe heat recovery heat pump, and the recovered condenser heat can be directed to your pool water. Each system is engineered around your pool, not sold off a shelf.
Custom solution: the pool configuration is engineered for each project and is not a stock product. Capacity and heat output are confirmed by an engineer in your proposal.
CONDENSER HEAT recovered
01 / THE PROBLEM
Pool water evaporates all day. The moisture stays in the hall unless something removes it.
Moisture settles on glass, cold walls and ceilings, then attacks finishes, metalwork and electrical equipment.
A permanently damp hall smells stale, feels sticky and invites mold in corners and behind panels.
Warm pool water keeps losing heat to the hall. Heat that the dehumidifier removes from the air can be put back to use instead of being thrown away.
In hot, humid climates, such as the Gulf, tropical coasts and humid lowlands, outdoor air carries a lot of moisture and the pool-hall air conditioning already works hard. Each door opening and each fresh-air intake brings more humid air in.
02 / HOW IT WORKS
The core is a packaged heat-pipe heat recovery heat pump with its own compressor. A heat-pipe module pre-cools the humid air before it reaches the evaporator and reheats the dry air afterwards.
Warm, humid air from the pool hall is drawn into the unit.
The heat-pipe module takes heat out of the incoming air before the evaporator, without extra energy input.
The evaporator cools the air below its dew point, so water condenses out and drains away.
The heat removed from the air, plus the compressor heat, is released at the condenser. It can reheat the supply air and can be directed to the pool water through a water-side exchanger.
CONDENSER HEAT recovered
Illustration of the principle only. It shows no temperatures, capacities or other values.
How much recovered heat reaches the pool water, and how much goes to the air or outdoors, is decided per project. A separate pool heater may still be needed.
03 / YOUR CONFIGURATION
Our standard heat-pipe heat recovery platform is adapted for pool use project by project. The options below are configured per project, and your engineer reviews them with you:
A corrosion-resistant water-side heat exchanger. The material is confirmed for your pool water treatment, whether chlorine or salt.
A corrosion-protection coating for the coils that sit in humid, chlorinated air.
An auxiliary outdoor heat rejection path that carries away excess heat when the pool does not need it.
Fresh-air intake, supply air direction and controls for pool-hall humidity and water temperature, set for your site.
From these inputs the engineer recommends a configuration, and tells you honestly if one unit is not enough.
04 / IS IT RIGHT FOR YOUR POOL?
We would rather tell you early than oversell a single unit.
Whether recovered heat covers all of your pool heating depends on the project. An auxiliary heater may still be part of the design.
05 / WHY NUNXIN
We design and build the equipment ourselves, so you deal with the factory, not a chain of resellers.
Our NX-FL2000BP-5 series platform uses a heat-pipe module and condenser heat recovery. The pool configuration is engineered on top of it for each project.
The water side, coil protection, heat rejection, power supply and controls are options configured for your pool and your site.
The standard platform takes about 15 days to build. The lead time of a pool configuration is confirmed in your proposal.
Send your pool details by form, WhatsApp or email. We review your request and reply with the questions we still need answered.
06 / PROCESS
Use the form or WhatsApp. A rough sketch or photo of the pool hall helps.
We check the moisture load, fresh air, water side and power supply, and come back with questions.
You receive the recommended configuration and a quotation in US dollars (FOB or CIF).
We build the system and confirm the lead time and shipping with you.
Installation and after-sales arrangements are discussed in the proposal.
07 / FAQ
Where an answer depends on your pool, we say so.
No. It is a custom solution. We adapt our heat-pipe heat recovery heat pump platform to your pool. A corrosion-resistant water-side exchanger, coil corrosion protection and auxiliary outdoor heat rejection are options configured per project. Capacity and heat output are confirmed by an engineer in your proposal.
In principle, yes. The heat removed from the hall air is released at the condenser, and part of it can be directed to the pool water through a water-side exchanger. How much heat reaches the water depends on the project, and a separate heater may still be needed.
It is meant for private villa pools, small hotel or club pools and small training pools. Larger pools may need several units or a different system. We confirm this after reviewing your pool and hall.
A corrosion-resistant water-side exchanger is a per-project option. We confirm the exchanger material for your water treatment in the proposal, and corrosion protection for the coils in the hall air is configured per project too.
Pool length, width and depth, whether the pool is in an enclosed hall, target water temperature, water treatment, available power supply and your country. A sketch or photo of the hall helps.
The standard platform takes about 15 days to build. The lead time for a pool configuration is confirmed in your proposal, and it does not include shipping or import procedures.
We are a manufacturer in Guangzhou, China. Installation and after-sales arrangements are discussed in the proposal.
No. Each system is configured to the project, so we quote per project in US dollars (FOB or CIF) after the engineer review.
This page describes a custom solution. It contains no performance figures because capacity and heat output depend on your pool, hall and site.
08 / ENGINEER REVIEW
Send us your pool details on WhatsApp or by email, and an engineer will review them and come back with any questions we still need answered. Useful details: pool size, whether the pool is in an enclosed hall, your country and your power supply.
WhatsApp +86 135 0154 8155
Email gwj@nunx-tec.com